Gigabit Ethernet Metro-Switch Board and Firmware Users Manual
DSS NETWORKS, INC. Version: 1.14g Page: 31
Note: ‘reg-base’ can be set from 0x22 – 0x28 for up to seven entries per port.
metro-sw> eereg show
reg idx: 01, rclass: 03 (reg set cmd)
base: 22, strt/incr: 00, end/cnt: 00
data: 01 08 00 01
In the example above, the data bytes comprising a 32-bit long word (0x01, 0x08, 0x00 0x01)
specify the VLAN id, Ethertype and Frame-Type for the port range starting at zero and ending at
0 (port 0 only).